A small machine shop has installed 220 cfm screw compressor to meet air requirement for various operation. The operating details are given below:
Shift reference
(8 hrs/ Shift)
Load time in sec
Un-Load time in sec
I
60
10
II
45
25
III
25
45
Load Power = 37 KW
Un-load power = 11 KW
Calculate the following:
1. Energy loss per day
2. Shift wise average air requirement in cfm
3. The plant has proposed to install a VFD for the compressor. Calculate the energy savings after installing the VFD operated compressor, if the VFD loss is 3 % of load power.
CALCULATION:
Ist shift consumption = ((60 / 70) x 37) + (10 / 70) x 11) x 8)
= (31.71+1.57) x 8
= 266.24 kWh
IInd shift consumption = ((0.64 x 37 + 0.36 x 11) x 8 )
= (23.68 + 3.96) x 8
= 221.12 kWh
IIIrd shift consumption = ((0.36 x 37 + 0.64 x 11) x 8)
= (13.32 +7.04) x 8)
= 162.88 kWh
Daily Total Energy consumption = (266.24 + 221.12 + 162.88)
= 650.24 kWh
Daily Energy loss due to unloading = (1.57 +3.96 +7.04) x 8
= 100.56 kWh
Daily load cycle Energy consumption = (650.24 – 100.56)
= 549.68 kWh
Daily energy consumption with VFD = (549.68 / 0.97)
= 566.68 kWh
Paper 3 Code : Pink
_______________________
Bureau of Energy Efficiency
15
Daily Energy loss due to VFD = (566.68 – 549.68)
= 17 kWh
Daily Net Energy savings with VFD compressor = (100.56 – 17)
= 83.56 kWh
Ist shift air requirement = (0.86 x 220)
= 189.2 cfm
IInd shift air requirement = (0.64 x 220)
= 140.8 cfm
IIIrd shift air requirement = (0.36 x 220)
= 79.2 cfm