CALCULATION OF DISCHARGE PIPE INNER DIAMETER FOR COMPRESSED AIR SYSTEM
Determine the discharge pipe inner diameter size (in mm) for compressed air system, having following parameters.
Compressed Air Flow at NTP (FAD) = 1000 Nm3/hr
Discharge Air Pressure = 7 bar(g)
Discharge Air Temperature = 35 o C
Air Velocity = 7 m/s.
Atmospheric Pressure = 1.013 bar
CALCULATION:
Actual Condition vs NTP Condition
P2 x V2 / T2 = P1 x V1 / T1
(1.013 + 7) x V2 / (273 + 35) = 1.013 x 1000 / 273
V1, actual flow rate = 142.6 m3/hr
= 0.0396 m3/s
Flow rate (m3/s) = Area, in mtr2 x Velocity (m/s)
Area, in mtr2 = Flow rate (m3/s) / Velocity (m/s)
= 0.0396 / 7 = 0.0057 m2
A = π (di2/4) = 0.0057 m2
Pipe, in mm = di = 0.085 m = 85 mm
= say 90 mm
MEASUREMENT OF ENERGY CONSERVATION IN BUILDING
Five energy conservation measures for energy use in buildings
1. Weather-stripping of Windows and Doors : Minimize exfiltration of cool air and infiltration of warm air through leaky windows and doors by incorporating effective means of weather stripping
2. Stripping. Self-closing doors should also be provided where heavy traffic of people is anticipated.
3. Temperature and Humidity Setting: Ensure human comfort by setting the temperature to between 23oC and 25oC and the relative humidity between 55% to 65%.
4. Chilled Water Leaving Temperature: Ensure higher chiller energy efficiency by maintaining the chilled water leaving temperature at or above 7o C. As a rule of thumb, the efficiency of a centrifugal chiller increases by about 2¼ % for every 1o C rise in the chilled water leaving temperature.
5. Chilled Water Pipes and Air Ducts: Ensure that the insulation of the chilled water pipes and ducting system is maintained in good condition. This helps to prevent heat gain from the surroundings.
6. Chiller Condenser Tubes: Ensure that mechanical cleaning of the tubes is carried out at least once every six months. Fouling in the condenser tubes in the form of slime and scales reduces the heat transfer of the condenser tubes and thereby reducing the energy efficiency of the chiller.
7. Cooling Towers: Ensure that the cooling towers are clean to allow for maximum heat transfer so that the temperature of the water returning to the condenser is less than or equal to the ambient temperature.
8. Air Handling Unit Fan Speed: Install devices such as frequency converters to vary the fan speed. This will reduce the energy consumption of the fan motor by as much as 15%.
9. Air Filter Condition: Maintain the filter in a clean condition. This will improve the heat transfer between air and chilled water and correspondingly reduce the energy consumption.
FLOW CONTROL METHOD OF INDUSTRIAL FAN
Briefly explain any three different methods of flow control for fans
Pulley Change:
When a fan flow change is required on a permanent basis, and the existing fan can handle the change in capacity, the volume change can be achieved with a speed change. The simplest way to change the speed permanently is with a pulley change. For this, the fan must be driven by a motor through a v-belt system.
Damper Control:
Dampers provide a means of changing air volume by adding or removing system resistance. This resistance forces the fan to move up or down along its characteristic curve, generating more or less air without changing fan speed.
Inlet Guide Vane:
Guide vanes are curved sections that lay against the inlet of the fan. Guide vanes pre-swirl the air entering the fan housing. This changes the angle at which the air is presented to the fan blades, which, in turn, changes the characteristics of the fan curve. Guide vanes are energy efficient for modest flow reductions – from 100 percent flow to about 80 percent. Below 80 percent flow, energy efficiency drops sharply.
Variable Speed Drive:
Variable speed operation involves reducing the speed of the fan to meet reduced flow requirements. Fan performance can be predicted at different speeds using the fan laws. Since power input to the fan changes as the cube of the flow, this will usually be the most efficient form of capacity control.
PUMP EFFICIENCY CALCULATION
PUMP EFFICIENCY CALCULATION
A pump is filling water in to a rectangular overhead tank of 5 m x 4 m with a height of 8 m. The inlet pipe to the tank is located at height of 20 m above ground. The following additional data is collected :
Pump suction : 3 m below pump level
Overhead tank overflow line : 7.5 m from the bottom of the tank
Power drawn by motor : 5.5 kW
Motor efficiency η : 92%
Time taken by the pump to fill the
overhead tank upto overflow level : 180 minutes Assess the pump efficiency.
CALCULATION
Volume of the tank = 5 x 4 x 7.5 = 150 m3 Flow
= 150/3 = 50 m3/hr
Hydraulic power = Q (m3/s) x total head (m) x 1000 x 9.81 /1000
= (50/3600) x (20 –(-3)) x 1000 x 9.81/1000
Hydraulic power = 3.13 kW
Power input to pump = 5.5 x 0.92 = 5.06 kW
Pump efficiency = 3.13/5.06 = 61.9%
STEAM TURBINE STANDARD OPERATING PROCEDURE
Steam Turbine standard operating procedures (SOPs) Lube oil system operation Pre-checks • Ensure lube oil tank level is normal • Ensure l...
-
VELOCITY AND PRESSURE DROP IN PIPES: Velocity The velocity of hydraulic fluid through a conductor (pipe, tube or hos...
-
Formulas to calculate mA from PV, LRV and URV The formula for calculating equivalent current (ma) from known process variable (PV), Lower ra...
-
DETERMINE THE SATURATED & SUPER HEATED STEAM VELOCITY/PRESSURE DROP & PIPE DIAMETER CALCULATION: Some information about ...